About digital coating thickness Accu CTG-4
technical Specification
Principal magnetic Induction Probe N
range 0- 1300um 0-1300um
accuracy 3%+2um
Resolution 0.1um /0.01mil
0.01um/0.01mil
calibration points zero/50/100/250/500/1000um
units -um, mil
Precision Calibration MethodsThe Accu CTG-4 offers both Zero and two-point calibration options, empowering users to achieve highly accurate measurements on varied substrates. Whether working with ferrous or non-ferrous metals, adjusting the calibration helps ensure consistent, reliable readings. This versatility supports high-quality control demands in industrial settings, accommodating diverse material properties and geometries for optimal performance every time.
Designed for Rugged Industrial ApplicationsConstructed with a tough ABS plastic case and a stainless-steel sensor tip, the Accu CTG-4 is built to withstand demanding environments. Compact in size and lightweight-at only 180g including batteries-this instrument suits on-site inspections and quality assurance tasks. Its large digital LCD, backlight, and data hold features facilitate effortless operation, even under challenging lighting or field conditions.
FAQ's of digital coating thickness Accu CTG-4:
Q: How do I calibrate the Accu CTG-4 for accurate measurements?
A: The Accu CTG-4 supports both Zero and two-point calibration. Start with a clean probe, and use the provided calibration foils or reference standards to perform Zero calibration (for baseline) or two-point calibration (for enhanced accuracy across the range). Calibration is initiated using the device menu, following step-by-step prompts on the LCD display.
Q: What types of surfaces can the Accu CTG-4 measure?
A: This gauge is suitable for measuring coating thickness on both ferrous (F) and non-ferrous (NF) metal surfaces. Common applications include paint, lacquer, and plating thickness inspection on steel, aluminum, and other industrial metal substrates.
Q: When should I use the Zero versus two-point calibration options?
A: Zero calibration is generally sufficient for quick checks or when measuring uniform thin coatings. Two-point calibration is recommended for greater accuracy, especially when measuring varied or thicker coatings, or when working with different substrate types.
Q: Where can I use the Accu CTG-4 in terms of environmental conditions?
A: The device is designed to operate effectively in environments with temperatures ranging from 0C to 40C and humidity levels up to 85% RH. Its robust construction makes it suitable for both laboratory and industrial field work.
Q: What is the process for measuring coating thickness with this device?
A: Simply turn on the device, ensure proper calibration, and place the sensor tip gently on the substrate within the minimum area and curvature requirements (F: 10 x 10 mm; 1.5 mm radius. NF: 15 x 15 mm; 3 mm radius). The LCD display will show the precise thickness value instantly.
Q: How does the data hold and storage function benefit me during usage?
A: The data hold function allows you to freeze the displayed reading for easy recording, while the storage capacity of up to 99 readings enables you to maintain a measurement log for further analysis or quality documentation without repeating tests.
Q: What are the advantages of using the Accu CTG-4 for industrial applications?
A: This gauge delivers high accuracy (2%+1m), versatility for different metals, and reliable measurement results. Its durable design, intuitive LCD interface, automatic power features, and portability offer significant operational efficiency and long-term value for manufacturers, suppliers, and quality inspectors in India.